Water Quality: Henryetta, OK

5 water systems • 9,176 people served

Multiple Health Violations
246
Total Violations
144
Health-Based Violations
5
Water Systems
9,176
Population Served

Water Quality Summary

Henryetta is served by 5 public water systems with a combined service population of 9,176 people, and has 246 EPA Safe Drinking Water Act violations on record. Critically, 144 of those are health-based violations, meaning one or more contaminants were detected above EPA-established safe levels — a serious public health concern. Henryetta's violation count is 7% below the national average for Oklahoma. Contaminants associated with violations include Contaminant 2920, Gross Alpha, Nitrate, Stage 2 DBP, TTHM.

Contaminants Found

Contaminant 2920
Gross Alpha

Alpha-emitting radioactive particles increase cancer risk, particularly from bone and other internal cancers.

Common source: Natural uranium and radium in geological formations

EPA limit: 15 pCi/L (excluding radon and uranium)

Nitrate

Causes methemoglobinemia (blue baby syndrome) in infants, reducing the blood's ability to carry oxygen.

Common source: Fertilizer runoff, septic systems, animal feedlots, natural deposits

EPA limit: 10 mg/L (as nitrogen)

Stage 2 DBP

Trihalomethanes and haloacetic acids that increase cancer risk and may cause adverse reproductive outcomes.

Common source: Chlorine disinfection reacting with natural organic matter in source water

EPA limit: TTHM: 0.080 mg/L; HAA5: 0.060 mg/L

TTHM

Total trihalomethanes are linked to increased risk of bladder cancer and adverse reproductive outcomes.

Common source: Reaction of chlorine disinfectants with naturally occurring organic matter in water

EPA limit: 0.080 mg/L (80 ppb)

Total Coliform (TCR)

Indicates possible presence of disease-causing organisms that can cause gastrointestinal illness.

Common source: Human and animal fecal waste, soil, vegetation

EPA limit: No more than 5% of monthly samples may be positive

Total Haloacetic Acids (HAA5)

Haloacetic acids are associated with increased cancer risk and potential reproductive and developmental effects.

Common source: Reaction of chlorine disinfectants with organic matter in treated water

EPA limit: 0.060 mg/L (60 ppb)

Water Systems Serving Henryetta

System Name PWSID Source Population Violations
HENRYETTA OK1020709 Surface Water 6,096 107
MCINTOSH CO. RWD #13 (WELLS) OK2005603 Groundwater 1,465 15
OKMULGEE CO. RWD #5 (BRYANT) OK2005604 Groundwater 750 13
OKMULGEE CO. RWD #21 OK3005607 Surface Water 625 72
KUSA RWD #3 OK3005603 Surface Water 240 39

Concerned About Your Water?

A home water filter can remove common contaminants. NSF-certified filters are tested against EPA standards.

Consider a reverse osmosis system for comprehensive filtration or a carbon filter for basic improvement.

Other Cities in Oklahoma

View all cities in Oklahoma →

Data Sources

Drinking water violation data from the EPA Safe Drinking Water Information System (SDWIS). Data includes all recorded violations for active community water systems.

Verify at epa.govSearch ECHO for OK